Trusted company that deals in quality-made products
Mon - Sat 8:00 - 6:30, Sunday - CLOSED
Urea Reagent Kit

Urea Reagent Kit

300.0 INR/Box

Product Details:

  • Size 100 tests, 500 tests, or as required
  • Packaging Type Kit form, sealed bottles
  • Physical State Liquid
  • Storage Instructions Store at 2-8 C (Refrigerated)
  • Shelf Life 18 Months
  • Purity >99%
  • Usage For in vitro diagnostic use only
  • Click to view more
X

Urea Reagent Kit Price And Quantity

  • 300.0 INR/Box
  • 10 Box

Urea Reagent Kit Product Specifications

  • 100 tests, 500 tests, or as required
  • Not available (Enzyme kit preparation)
  • 18 Months
  • Other
  • Store at 2-8 C (Refrigerated)
  • Liquid
  • Kit form, sealed bottles
  • Reagent Grade
  • >99%
  • For in vitro diagnostic use only
  • Clear colorless to pale yellow solution
  • >99%

Urea Reagent Kit Trade Information

  • Ahmedabad & Mumbai
  • Cash Advance (CA), Cash in Advance (CID), Cheque
  • 10000 Box Per Week
  • 1 Days
  • No
  • If order is confirmed we will reimburse the sample cost
  • Asia, South America, Africa
  • All India
  • ISO 13485:2016, ISO 90001, CE, MDR:2017

Product Description

This is an in-vitro diagnostic (IVD) reagent kit for the quantitative determination of urea in human serum, plasma, and urine samples on a photometric system. The kit utilizes a kinetic, fixed-time enzymatic method based on Urease and Glutamate Dehydrogenase (GLDH). It is a vital tool for assessing kidney function and diagnosing various metabolic conditions, as abnormal urea levels can indicate kidney problems, urinary tract obstructions, or liver failure.

Reliable Quantification with Urease-GLDH Principle

This urea reagent kit employs a robust enzymatic approach, where urease hydrolyzes urea into ammonia and carbon dioxide. Subsequently, the ammonia is quantified using a GLDH-based reaction, ensuring high specificity and accuracy. The supplied protocol explains each step in detail, making the process reproducible and straightforward even for routine laboratory use.


Exceptional Sensitivity and Range for Clinical Needs

Detecting urea levels as low as 1 mg/dL, this kit covers a wide linearity range from 5 to 200 mg/dL. This versatility accommodates varied clinical and diagnostic requirements. Each kit includes urea standards for calibration and control reagents, supporting reliable interpretation of patient results every time.


Safe, Easy Handling and Long Shelf Life

Manufactured in India and graded for reagent quality, this liquid-form kit is non-hazardous according to standard guidelines. Its conveniently packaged in sealed bottles and requires only 10-20 L of sample. With a 24-month shelf life and recommended storage at 2-8C, it remains stable and ready for use throughout its duration.

FAQs of Urea Reagent Kit (Urease-GLDH Method) for Quantitative Determination:


Q: How does the Urea Reagent Kit (Urease-GLDH Method) work for urea quantification?

A: The kit relies on a two-step enzymatic process: first, urease converts urea present in the sample to ammonia and carbon dioxide. Next, ammonia is quantitatively measured using a GLDH enzymatic reaction. This approach ensures high specificity and reliable determination of urea concentration in serum or plasma.

Q: What is the required sample volume and linearity range for this kit?

A: You only need 10 to 20 L of serum or plasma for each test. The kit provides accurate results for urea concentrations in the range of 5 to 200 mg/dL, making it suitable for most clinical laboratory applications.

Q: When should I calibrate and whats included in the calibration process?

A: Calibration should be performed prior to running patient samples, using the urea standard provided in the kit. This routine step ensures the accuracy of each quantitative assay and improves consistency in results.

Q: Where should the kit be stored and how long is it usable?

A: The kit must be stored refrigerated at 2-8C to maintain its integrity and performance. When kept as advised, it has a shelf life of 24 months from the date of manufacture.

Q: What precautions should be taken regarding safety, disposal, and hazard information?

A: This reagent kit is classified as non-hazardous per regulatory standards. Nevertheless, follow your local guidelines for chemical waste disposal. Always refer to the accompanying protocol leaflet for additional handling instructions.

Q: How is quality control ensured during testing?

A: The kit includes control reagents to help laboratories routinely monitor the performance of each test run. Using these controls, you can verify both the accuracy and reliability of your results.

Q: What are the main advantages of using this urea reagent kit in a laboratory setting?

A: Key benefits include high sensitivity, reliable linearity, minimal sample volume requirements, and a non-hazardous composition. Comprehensive instructions and built-in quality controls contribute to ease of use and dependable outcomes for routine urea determinations.

Technical Details 

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top